FF-ST4C09AM2 – Honeywell
In-Stock: 1
Available, can ship immediately
Part Details:
FF-ST4 Series.
Model/Part No :- FF-ST4C09AM2.
Resolution (min. object detection size) : 14 mm, 18 mm, 30 mm, 80 mm.
Nominal scanning range : 0 m to 3.5 m (for 14 mm resolution); 0.25 m to 10 m (for 18 mm, 30 mm, 80 mm resolutions).
Angle of divergence : max. ±5° above 3 m (as per IEC/EN 61496-2).
Emitting light source : infrared, pulsed, 880 nm.
Supply voltage : 24 Vdc (±20%) for the emitter and the receiver.
Power consumption : 5 W max. for the emitter, 5 W max. for the receiver.
Output type : 2 safety solid state outputs, push-pull/PNP type with Normally Open characteristics.
Switching capability : 350 mA max. at 24 Vdc.
Restart time after power up : >1 s (automatic mode).
Restart time after beam release : 80 ms (without EDM), 150 ms (with EDM).
Leakage current : 0.25 mA.
Load impedance : 70 Ohm min., 5 kOhm max.
Voltage drop : <2.3 Vdc.
Load turn-on voltage : 5 V min. on resistive loads, 7 V min. on inductive loads.
Test pulse width/recurrence : 2 pulses (width 200 us and 75 us), separated by 300 us, frequency from 3.3 ms to 8 ms (depending on height).
Protections : short-circuits and cross-faults, overloads (0.4 A max./0 Vdc; 0.9 A max./24 Vdc), reversed polarity, micro-cut-off 10 ms (100% voltage breakdown, 10 Hz).
Max. cable length : 100 m [328.08 ft] (capacitance: 10 nF).
External contact type : relay contact, or static (solid state) PNP or static (solid state) NPN (automatic recognition - no push-pull output allowed).
Filtering time : 20 ms by default, 150 ms on the EDM input.
Voltage switching thresholds (high/low) : 14.5 Vdc min., 4.5 Vdc (complies with IEC 61131-2, for type 2 sensors).
Input current (high/low) : 20 mA; 10 mA at 24 Vdc.
ax. voltage : 29 Vdc.
Housing material : aluminum alloy.
End cap material : za mak.
Window material : PMMA (Polymethylmethacrylate).